Inspection Detail
Inspection: 120335484 - Fume Tech Inc.
Inspection Information - Office: Sacramento District Office
Site Address:
Fume Tech Inc.
2000 Channel Drive
West Sacramento, CA 95691
Mailing Address:
P. O. Box 681, Citrus Heights, CA 95611
Union Status: NonUnion
SIC:7342
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/31/1994
Emphasis:
Case Closed: 02/07/1995
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361498819 |
Investigation Summary
At 11:27 a.m. on August 25, 1994, Employee #1 was attempting to activate a 440V fan with a motor controller switch. A rodent in the controls crossed the contacts, resulting in an explosion and fireball. Employee #1 suffered 1st- and 2nd-degree burns on his arms and face. He was hospitalized.
Keywords: BURN, FAN, EXPLOSION, ARM, FACE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120335484 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |