Inspection Detail
Inspection: 120333950 - Fountain Suites
Inspection Information - Office: Sacramento District Office
Site Address:
Fountain Suites
321 Bercut Drive
Sacramento, CA 95814
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:7011
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/26/1994
Emphasis:
Case Closed: 03/21/1996
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361351828 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $335 | $0 | $335 |
| Current Penalty | $0 | $0 | $0 | $335 | $0 | $335 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3203 A07 F | 12/27/1994 | 01/06/1995 | $335 | $335 | $0 | - |
Investigation Summary
Employee #1, a hotel maintenance supervisor, was cleaning the swimming pool filter elements when the top section of the filter blew off. The top struck him in the face and head, causing a concussion, skull fracture, and facial lacerations. The accident probably occurred because the employee did not reassemble the V-band clamp properly before turning on the filter pump unit. The pressure built up in the unit, blowing the top section off.
Keywords: FRACTURE, WORK RULES, CLEANING, LACERATION, POOL, HIGH PRESSURE, STRUCK BY, CONCUSSION, FLYING OBJECT, FACE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120333950 | Hospitalized injury | Concussion | Not specified mechanics and repairers |