Powered by GoogleTranslate

Inspection Detail

Inspection: 120327804 - Netto Trucking Inc., Netto Ag. Inc.

Inspection Information - Office: Fresno District Office

 

Inspection Nr: 120327804
Report ID: 0950625
Date Opened: 09/19/1995

Site Address:
Netto Trucking Inc., Netto Ag. Inc.
Grangeville Blvd & 12th Ave
Hanford, CA 93230

Mailing Address:
10044 Flint Avenue, Hanford, CA 93230

Union Status: NonUnion

SIC:0722

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/18/1996

Emphasis:

Case Closed: 05/28/1997


Related Activity
Type Activity Nr Safety Health
Accident 361354798
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 5 5
Initial Penalty $0 $0 $0 $800 $0 $800
Current Penalty $0 $0 $0 $800 $0 $800
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3578 G 03/18/1996 04/19/1996 $160 $160 $0 -  
2. 01002 Other 4650 D 03/18/1996 09/20/1995 $160 $160 $0 -  
3. 01003 Other 6151 E02 03/18/1996 09/20/1995 $160 $160 $0 -  
4. 01004 Other 4799 03/18/1996 04/19/1996 $160 $160 $0 -  
5. 01005 Other 4848 A 03/18/1996 04/19/1996 $160 $160 $0 -  

Investigation Summary

Investigation Nr: 170717078
Event: 03/29/1995
Employee's hand amputated in paddle blower fan

At 7:45 p.m. on March 29, 1995, Employee #1 was operating a John Deere harvester, Unit #4, in a field of green barley when the operator of Unit #2 requested assistance. Employee #1 briefly operated Unit #2 and ascertained that there was a clog around the paddle from the blower or spout. Employee #1 then departed on his machine to complete another round while the operator of Unit #2 went for tools. On his return, the Unit #2 operator removed the lower inspection port cover of the paddle blower fan. Employee #1, during his check for the clog, had left the engine running with the main drive clutch in the 'off' position; this time, Employee #1 did not ensure that the engine was turned off and the controls were in the 'off' mode. He reached into the lower inspection port of the paddle blower fan to clear the clog, which was actually located in the spout system above the blower fan. The fan was rotating, and Employee #1's hand was amputated. He was transported by his foreman to Hanford Community Hospital. After being stabilized, Employee #1 was transferred to Davis Medical Center, San Francisco, where attempts to reattach his hand were unsuccessful.

Keywords: AMPUTATED, FAN, AGRICULTURE, WORK RULES, FARM MACHINERY, STRUCK AGAINST, HARVESTER, LOCKOUT, CLOGGED, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120327804 Hospitalized injury Amputation Farm workers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.