Inspection Detail
Inspection: 120322227 - Coast & Valley Carpet Care
Inspection Information - Office: Van Nuys District Office
Site Address:
Coast & Valley Carpet Care
11808 San Tropez Pl
Moorpark, CA 93021
Mailing Address:
17563 Gladesworth Lane, Fair Oaks Ranch, CA 91387
Union Status: NonUnion
SIC:7217
NAICS: 561740/Carpet and Upholstery Cleaning Services
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/16/2006
Emphasis:
Case Closed: 12/31/2007
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101113371 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $0 | $0 | $0 | $875 | $0 | $875 |
| Current Penalty | $0 | $0 | $0 | $875 | $0 | $875 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3203 A07 | 10/16/2006 | 11/03/2006 | $375 | $375 | $0 | - | ||
| 2. | 01002 | Other | 3662 | 10/16/2006 | 11/03/2006 | $500 | $500 | $0 | - |
Investigation Summary
In the evening of May 6, 2006, Employees #1 and #2 were cleaning the carpets of a two-story condominium. They were using a long extended hose attached to a Linamar Model Number LX 790 gasoline-powered carpet cleaning unit, with Serial Number 88-5960-02, located in a Ford Econoline 250 van. The Ford van had been backed into the connecting garage of the condo. The door of the garage, which connects to the condo, was open to allow the passage of the carpet cleaning hose. One passerby observed the two employees working at 9:30 p.m. with the garage door open, but when he came back at 9:50 p.m., the door was closed. Carbon monoxide gas from the carpet cleaning unit entered the condominium and asphyxiated the two employees. They were found at the foot of the stairwell near the front door. It is not certain that the owner of the carpet cleaning company knew the two were working on this job, and the owner indicated the workers were not employees.
Keywords: ENCLOSED SPACE, ASPHYXIATED, CARPET, CLEANING, ENGINE, HOSE, PUMP, CARBON MONOXIDE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120322227 | Fatality | Poisoning(Systemic) | Janitors and cleaners | ||
| 2 | 120322227 | Fatality | Poisoning(Systemic) | Janitors and cleaners |
Translate