Powered by GoogleTranslate

Inspection Detail

Inspection: 120320908 - Test Laboratories Dba Brewster Foods Inc.

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 120320908
Report ID: 0950643
Date Opened: 07/11/2003

Site Address:
Test Laboratories Dba Brewster Foods Inc.
7121 Canby Ave.
Reseda, CA 91335

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5159

NAICS: 424590/Other Farm Product Raw Material Merchant Wholesalers


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/07/2004

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 12/31/2007


Related Activity
Type Activity Nr Safety Health
Accident 362513749
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2 4
Current Violations 3 3
Initial Penalty $14,625 $0 $0 $330 $0 $14,955
Current Penalty $0 $0 $0 $2,600 $0 $2,600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 23400023 01/07/2004 02/09/2004 $100 $165 $0 01/21/2004 F - Formal Settlement  
2. 01002 Other 23400016 A 01/07/2004 02/09/2004 $0 $165 $0 01/21/2004 F - Formal Settlement Citation has been deleted.
3. 02001 Other 5174 A 01/07/2004 01/20/2004 $2,500 $12,600 $0 01/21/2004 F - Formal Settlement  
4. 03001 Other 5194 G02 C 01/07/2004 02/02/2004 $0 $2,025 $0 01/21/2004 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201116324
Event: 07/11/2003
Employee Is Burned When Combustible Powder Explodes

At approximately 12:00 a.m. on July 11, 2003, an explosion occurred at a company that blended and supplied natural ingredients for food suppliers. Prior to the accident, Employee #1 poured grapefruit powder from a plastic-lined cardboard box, 260 double-wall carton, into a large stainless-steel cone mixer, while he stood on an elevated platform in the blending room. A Baldor electric motor, 115/230 volts, powered the 800-kilogram cone blender. The plastic-lined cardboard box for the powder measured 13-in. by 13-in. by 29-in. During the process of pouring, an explosion occurred. Prior to discharging the grapefruit powder into the mixer, a coworker, the lead person, weighted the material, and had it lifted to the top platform in the blending room. He said he heard a noise and turned around and saw fire. The grapefruit powder was later tested and found to be combustible. An interview with the fire department arson investigator indicated that the overhead fan was not operating at the time of the explosion. Various potential ignition sources existed, including electrical lighting, an electrical outlet, a fan motor, and static produced by the pouring operation. According to the doctor's report, Employee #1 was hospitalized with second-degree burns over 70 percent of his body,

Keywords: BURN, STATIC ELECTRICITY, FOOD PREPARATION, POURING, WORK RULES, FIRE, MIXER, EXPLOSION, COMBUSTIBLE DUST, POWDER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120320908 Hospitalized injury Burn/Scald(Heat) Production helpers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.