Powered by GoogleTranslate

Inspection Detail

Inspection: 120318969 - Tower Structures Inc.,

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 120318969
Report ID: 0950643
Date Opened: 05/07/2003

Site Address:
Tower Structures Inc.,
19020 Vanowen St.
Reseda, CA 91335

Mailing Address:
430 Olive Ave., Vista, CA 92083

Union Status: NonUnion

SIC:1791

NAICS: 238120/Structural Steel and Precast Concrete Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/26/2003

Emphasis: S:Construction (Cship)

Case Closed: 03/14/2007


Related Activity
Type Activity Nr Safety Health
Accident 362511578
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $14,400 $0 $0 $0 $0 $14,400
Current Penalty $0 $0 $0 $825 $0 $825
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 8615 G 09/26/2003 10/14/2003 $825 $14,400 $0 10/06/2003 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201115821
Event: 03/27/2003
Employee injured in fall from communication tower

Employee #1 and several coworkers were dismantling a 180-foot communications tower. They had dismantled all but the lower section of the tower. This bottom section consisted of a 20-foot three-legged section which had been unbolted from three 5-foot concrete piers, placed upright on the ground, and rigged to a boom truck crane. According to Employee #1, he and another worker had climbed up the vertical legs of the tower and had reached the points where they were to unbolt the horizontal girts of the tower section. Both employees were wearing fall protection, which included harnesses and lanyards. Before Employee #1 unbolted his section, the Foreman, who was positioned on the ground on one of two forklifts, told him to go to the other side and unbolt that section first. Employee #1 then unhooked his lanyard from the anchor in the flange, wrapped the lanyard on the girt and began to "scoot across the girt." When he got to the area of the girt where the sling from the boom truck was attached, he was faced with the obstacle of getting around this sling. The hook on his lanyard which he needed to anchor to the girt, would not fit around the diameter of the girt, and he had not been provided with the proper equipment to enable him to anchor to the girt. He then unhooked his "fall restraint" lanyard, with the intention of wrapping it around the girt on the other side of the sling, to reposition himself on the other side of the rigging. Before he could hook the lanyard back into his "spreader bar," he fell off the girt, 20 feet to the ground. His injuries included three pelvic fractures, a fractured sacrum, three fractured ribs, and a fracture to his right wrist. He was hospitalized at Northridge Hospital for 6 or 7 days.

Keywords: FRACTURE, COMMUNICATION TOWER, PPE, PELVIS, RIB, FALL, FALL PROTECTION, TOWER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120318969 Hospitalized injury Fracture Structural metal workers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close