Powered by GoogleTranslate

Inspection Detail

Inspection: 120313796 - Anheuser-Busch, Llc.

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 120313796
Report ID: 0950643
Date Opened: 04/17/2002

Site Address:
Anheuser-Busch, Llc.
15800 Roscoe Blvd.
Van Nuys, CA 91406

Mailing Address:
, , 00000

Union Status: Union

SIC:2082

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/12/2002

Emphasis:

Case Closed: 07/07/2005


Related Activity
Type Activity Nr Safety Health
Accident 362518599
Complaint 201096864 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $420 $0 $420
Current Penalty $0 $0 $0 $420 $0 $420
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3321 A 09/12/2002 09/17/2002 $420 $420 $0 W - Empr Withdrew  

Investigation Summary

Investigation Nr: 201114295
Event: 03/19/2002
Employee injured after struck by water hose

At approximately 6:00 p.m. on March 20, 2002, Employee #1 of Anheuser-Busch, Inc., was washing the floor with water in Stockhouse No. 6 with a hose. Employee #1 inadvertently connected the hose which had a 3-in. brass fitting to a 30-psi carbon dioxide line instead of the water line which was next to it. The water line was labeled but the line for the carbon dioxide was not labeled. When Employee #1 turned on the pressure, the end of the hose struck the employee in the head. The hose was estimated to have a diameter of 2 inches and was reported to be approximately 25 feet in length. Employee #1 was transported by the company truck to the company doctor in Sherman Oaks. He was then taken to a doctor in Beverly Hills since the CAT scan in the clinic was down. He was released to go home but instead checked into Encino/Tarzana Medical Center and had surgery. He was in the hospital for 5 days for laceration and fracture of the scalp.

Keywords: HOSE, CARBON DIOXIDE, STRUCK BY

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120313796 Hospitalized injury Fracture Miscelaneous food preparation occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close