Inspection: 120313747 - Bentley-Simonson Inc.

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 120313747
Report ID: 0950643
Date Opened: 02/13/2003

Site Address:
Bentley-Simonson Inc.
14201 Paxton St.
Pacoima, CA 91345

Mailing Address:
1746-F South Victoria Ave., Box 382, Ventura, CA 93003

Union Status: NonUnion

SIC:4925

NAICS: 221210/Natural Gas Distribution


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/29/2003

Emphasis: N:Petro

Case Closed: 04/11/2005


Related Activity
Type Activity Nr Safety Health
Accident 362512428
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $18,000 $0 $0 $750 $0 $18,750
Current Penalty $14,400 $0 $0 $750 $0 $15,150
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 05/29/2003 07/01/2003 $375 $375 $0 03/04/2004 F - Formal Settlement  
2. 01002 Other 14300007 B03 05/29/2003 07/01/2003 $375 $375 $0 03/04/2004 F - Formal Settlement  
3. 02001 Serious 6535 C 05/29/2003 06/03/2003 $14,400 $18,000 $0 03/04/2004 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201115268
Event: 12/27/2002
Two employees injured by natural gas drilling rig fire

At 12:15 p.m. on December 27, 2002, two employees were injured at a natural gas production facility. The employer, Bentley- Simonson Inc, is an independent oil company that produces both oil and gas. The site where the employees were injured was a recently acquired natural gas field. At the time of the accident, Employee #1, a field operator, and Employee #2 , a construction superintendent, were responding to a failure of a chiller alarm for a compressor. The equipment they were working on was composed of a chiller unit or low temperature separator, that cools the natural gas to remove the natural gas liquids and a glycol dehydration unit that absorbs water from the gas which goes through a reboiler to boil off the water. The two employees tried to bleed the chiller down by opening a upper inlet valve. This did not work, so Employee #1 opened a lower valve on the stabilizer reflux vessel. At the time of the incident, both employees were standing on the east side of the equipment with the stabilizer between them and the glycol dehydration unit. Liquid natural gas drained out on the ground. The vapors and gases traveled up through an opening of the flame arrestor portion of the glycol dehydration unit and were ignited by a pilot light. This resulted in a fire ball with burns to the two employees. Employee #1 had first-degree burns to the arms and face but was not hospitalized. Employee #2 received second-degree burns to the left arm and the right hand as well as minor first-degree burns to the face, and was hospitalized for 11 days.

Keywords: BURN, COMPRESSOR, FIRE, NATURAL GAS, VALVE, ARM, FACE, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120313747 Hospitalized injury Burn/Scald(Heat) Supervisors, extractive occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.