Powered by GoogleTranslate

Inspection Detail

Inspection: 120309646 - Equilon Enterprises

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 120309646
Report ID: 0950643
Date Opened: 08/30/2001

Site Address:
Equilon Enterprises
6451 Rosedale Hwy.
Bakersfield, CA 93308

Mailing Address:
P.O. Box 1476, Bakersfield, CA 93302

Union Status: Union

SIC:2911

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 02/13/2002

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 01/23/2004


Related Activity
Type Activity Nr Safety Health
Accident 362501017
Accident 362502635
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 3 7
Current Violations 2 2 4
Initial Penalty $28,125 $0 $0 $1,125 $0 $29,250
Current Penalty $20,700 $0 $0 $3,300 $0 $24,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 5144 C01 02/22/2002 03/27/2002 $0 $375 $0 06/07/2002 F - Formal Settlement Citation has been deleted.
2. 01002 Other 5189 G04 02/22/2002 03/27/2002 $0 $375 $0 06/07/2002 F - Formal Settlement Citation has been deleted.
3. 01003 Other 5194 H02 E 02/22/2002 03/27/2002 $0 $375 $0 06/07/2002 F - Formal Settlement Citation has been deleted.
4. 02001 Other 3382 A 02/22/2002 03/27/2002 $600 $3,375 $0 06/07/2002 F - Formal Settlement  
5. 03001 Other 5144 D03 A 02/22/2002 03/27/2002 $2,700 $3,375 $0 06/07/2002 F - Formal Settlement  
6. 04001 Serious 5155 C02 02/22/2002 03/27/2002 $2,700 $3,375 $0 06/07/2002 F - Formal Settlement  
7. 05001 Serious 5189 J02 02/22/2002 03/27/2002 $18,000 $18,000 $0 06/07/2002 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201113545
Event: 08/22/2001
Employee injured when exposed to chlorine gas cylinder leak

On August 22, 2001, Employee #1 was employed by Equilon Enterprises. Employee #1 was exposed to an acute hazardous substance, chlorine gas, while changing the regulator on a one-ton gas cylinder. Employee #1 experienced acute chlorine exposure symptoms, eye and throat irritation, intense coughing and vomiting, as a result of the inhalation of chlorine gas. Employee #1 was in the hospital for approximately three days.

Keywords: EYE, THROAT, CYLINDER, GAS, CHLORINE, POISONING, COUGH, VOMIT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120309646 Hospitalized injury Poisoning(Systemic) Mechanical controls and valve repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.