Inspection Detail
Inspection: 120309240 - Del West Engineering
Inspection Information - Office: Van Nuys District Office
Site Address:
Del West Engineering
28128 W. Livingston Ave.
Valencia, CA 91355
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3491
NAICS: 332911/Industrial Valve Manufacturing
Inspection Type: Complaint
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/01/2001
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 08/01/2001
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Complaint | 78701703 | Yes |
Investigation Summary
Employee #1 was opening one valve of a six pack of compressed gas cylinders. The six pack was connected to a manifold and each compressed gas cylinder had its own line going into the manifold. Employee #1 was opening one of the valves when the hose line blew which caused two other lines to either blow or become disconnected. All three oxygen lines were whipping in the air and one struck him in the face. He also suffered third-degree burns on the inside of his arm. The cause of the burn was undetermined. Employee #1 was hospitalized.
Keywords: BURN, CYLINDER, COMPRESSED GAS, LACERATION, STRUCK BY, ARM, FACE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120309240 | Hospitalized injury | Burn(Chemical) | Lathe and turning machine operators |