Powered by GoogleTranslate

Inspection Detail

Inspection: 120307558 - Alcoa Fastening Systems

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 120307558
Report ID: 0950635
Date Opened: 06/05/2002

Site Address:
Alcoa Fastening Systems
3000 W Lomita Blvd
Torrance, CA 90505

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3452

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/10/2002

Emphasis:

Case Closed: 07/08/2009


Related Activity
Type Activity Nr Safety Health
Accident 362431553
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $18,000 $0 $0 $750 $0 $18,750
Current Penalty $18,000 $0 $0 $750 $0 $18,750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 14300007 B03 10/10/2002 11/07/2002 $375 $375 $0 -  
2. 01002 Other 4202 C 10/10/2002 11/07/2002 $375 $375 $0 -  
3. 02001 Serious 4211 B 10/10/2002 10/15/2002 $18,000 $18,000 $0 -  

Investigation Summary

Investigation Nr: 201034279
Event: 05/22/2002
Employee injured while operating punch press

On May 22, 2002, Employee #1 was working for Fairchild Fastener, an employer that manufactures industrial fasteners primarily for aerospace industries. The employee was operating a full revolution Benchmaster punch press, Model 1-7-3, with a 4-ton capacity. The actuation of the machine cycle depends on a simultaneous two-hand trip. The distance between the hand trip locations and the die/tool location was 15 inches. The employee was performing crimping/closing-in of the beam of Part Number TR 26036N1032-1 (about 0.5 inches in length) and was seated about 7 inches to 8 inches in front of the press. The employee was nearing the completion of the production run. During one of the cycles, after the employee actuated the two-hand trip system and as she reached out to pick up the finished part with her right hand, the slide with the tool came down again (without her actuating the two-hand trip) and smashed (over the bottom die) the tip of her right index finger. The employee was transported to Torrance Memorial Medical Center where the tip of her finger was amputated.

Keywords: AMPUTATED, FINGER, CRUSHED, PUNCH PRESS

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120307558 Hospitalized injury Fracture Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close