Inspection Detail
Inspection: 120303797 - Ancon Marine
Inspection Information - Office: Long Beach District Office
Site Address:
Ancon Marine
Opp Dominguez Canal
Wilmington, CA 90731
Mailing Address:
2250 E Dominguez, Carson, CA 90801
Union Status: Union
SIC:8741
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/25/2001
Emphasis:
Case Closed: 01/23/2004
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362403685 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $5,400 | $0 | $0 | $245 | $0 | $5,645 |
| Current Penalty | $0 | $0 | $0 | $570 | $0 | $570 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3203 A | 05/29/2001 | 06/26/2001 | $245 | $245 | $0 | 06/25/2001 | W - Empr Withdrew | |
| 2. | 02001 | Other | 3203 A07 C | 05/29/2001 | 06/26/2001 | $325 | $5,400 | $0 | 06/25/2001 | F - Formal Settlement |
Investigation Summary
At approximately 3:40 p.m. on January 4, 2001, Employee #1 and several other workers were cleaning out a storm water culvert of oil, mud, and other debris. The culvert was 1.5 to 2 ft deep and 3 to 4 ft wide. The equipment used was an open-fired hot water and steam generator manufactured by Sandy Equipment, Model 1.5 MBTU Boiler Steamer Unit, diesel fired. The water steam is delivered from the equipment at 200 to 400 degrees Fahrenheit. Employee #1 wore a Nomex suit, hard hat, safety glasses, knee high rubber boots, and rubber gloves. When they finished the lead man gave the order for the boots of the laborers to be cleaned using the hot water steam generator gun. This order directly contradicts the employer's general safety rule number seventeen, do not hot water wash or steam clean protective clothing or boots while worn, they must be removed for such cleaning. The hot water steam gun operator caught the wand of the gun in the top of Employee #1's right boot, filling it with hot water. Employee #1 was hospitalized with second and third degree burns to his right thigh and received skin grafts.
Keywords: BURN, STEAM CLEANER, PPE, THIGH, STEAM, HOT WATER, LEG
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120303797 | Hospitalized injury | Burn/Scald(Heat) | Laborers, except construction |
Translate