Inspection Detail
Inspection: 120297460 - Santa Catalina Island Co
Inspection Information - Office: Long Beach District Office
Site Address: 
			   Santa Catalina Island Co
			   Hermit Gulch Camp Groud
Avalon, CA 90704
Mailing Address: 
			   P O Box 737, Avalon, CA 90704
Union Status: NonUnion
SIC:7996
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/27/1997
Emphasis:
Case Closed: 05/19/1999
| Type | Activity Nr | Safety | Health | 
|---|---|---|---|
| Accident | 362026650 | 
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total | 
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 1 | 1 | 2 | |||
| Initial Penalty | $5,000 | $0 | $0 | $375 | $0 | $5,375 | 
| Current Penalty | $420 | $0 | $0 | $375 | $0 | $795 | 
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 | 
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note | 
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 342 A | 08/28/1997 | 09/03/1997 | $375 | $375 | $0 | 03/11/1998 | J - ALJ Decision | |
| 2. | 02001 | Serious | 5416 C | 08/28/1997 | 09/03/1997 | $420 | $5,000 | $0 | 03/11/1998 | J - ALJ Decision | 
Investigation Summary
Employee #1, a campground manager, worked for a resort operator on Catalina Island. On the day of the accident, he was at the Hermit Gulch Campground, attempting to light a 100 gallon propane A.O. Smith water heater, model FGR 100 231, serial #ML94-0079063-S-06. The main propane tank for the water heater had just been replaced, and the hot water for the upper showers was turned off. The propane water heater was located in an enclosed, approximately 4 ft wide by 15 ft long area of the building that housed the showers. Employee #1 bled the propane line while lying down on a foam camping mat inside the water heater room. He then went to empty the trash cans around the campground so that the propane could disperse in the air. After about 15 minutes, Employee #1 attempted to light the pilot again while lying on the foam mat. He had the pilot lit, and was pulling out the sparker when a ball of fire erupted. Employee #1 sustained second-degree burns to his hands. He failed to test the air to determine if the concentration of the flammable vapors exceeded 25% of the lower explosive limit prior to introducing a source of ignition.
Keywords: BURN, PILOT LIGHT, FLAMMABLE VAPORS, WORK RULES, FIRE, HOT WATER TANK, PROPANE, SPARK, HAND
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation | 
|---|---|---|---|---|---|---|
| 1 | 120297460 | Hospitalized injury | Burn/Scald(Heat) | Recreation workers | 