Powered by GoogleTranslate

Inspection Detail

Inspection: 120278841 - A V Builders Corp

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 120278841
Report ID: 0950632
Date Opened: 02/01/2001

Site Address:
A V Builders Corp
12039 Calle De Leon Apt 17
El Cajon, CA 92019

Mailing Address:
4950 Waring Rd Ste Z, San Diego, CA 92129

Union Status: NonUnion

SIC:1542

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/21/2001

Emphasis: S:Construction (Cship)

Case Closed: 11/08/2001


Related Activity
Type Activity Nr Safety Health
Accident 362065443
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $0 $0 $0 $555 $0 $555
Current Penalty $0 $0 $0 $555 $0 $555
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 1509 A 05/24/2001 05/30/2001 $185 $185 $0 -  
2. 01002 Other 1510 A 05/24/2001 05/30/2001 $185 $185 $0 -  
3. 01003 Other 1512 B 05/24/2001 05/30/2001 $185 $185 $0 -  

Investigation Summary

Investigation Nr: 120278841
Event: 01/31/2001
Electric Shock - Contact with Energized Conductor thru Tool

An apprentice carpenter working for a general contractor for remodeling projects was installing support brackets and bolts on the foundation of a condominium unit. He was working near an exterior electric hot water heater on the patio of the unit. He had installed the hold-down bolts and was straightening one of them with a pry bar so that he could install the bracket. The pry bar, which was pressed against the wall support stud, penetrated the sheath and insulation of a 120-volt nonmetallic-sheathed cable. The employee was electrocuted.

Keywords: ELEC INSULATION, E GI III, ELECTRICAL, ELECTRIC CABLE, ELECTROCUTED, HAND TOOL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120278841 Fatality Electric Shock Carpenter apprentices
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close