Inspection Detail
Inspection: 120277140 - 4 Point Pipeline Construction
Inspection Information - Office: San Diego District Office
Site Address:
4 Point Pipeline Construction
Shawridge And Vine
San Diego, CA 92130
Mailing Address:
2160-F Fletcher Pkwy, El Cajon, CA 92020
Union Status: NonUnion
SIC:1731
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/28/2000
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 11/28/2000
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361643323 |
Investigation Summary
At approximately1:30 p.m. on May 30, 2000, Employee #1, a construction laborer, was in a trench working on the installation of a manhole in a storm drain system. A front loader was approaching the trench with a bucket of gravel when it lost use of its brakes and could not stop. The loader operator, realizing that the brakes were failing, attempted to lower the bucket to the ground to stop his machine. The foreman shouted for all workers to get out of the trench, but Employee #1 was not able to escape in time. The loader bucket struck the manhole assembly and the lower ring crushed Employee #1 against the wall of the trench. The foreman directed coworkers to use an excavator to remove the lower ring and free him. Employee #1 suffered fractures to his left pelvis, arm, shoulder, and ribs. Paramedics arrived in approximately 10 minutes and transported him to an area trauma center, where he underwent major surgery to repair a punctured lung and damage to his hip and spleen. At the time this report was written, Employee #1 faced a lengthy recovery and extensive therapy, with an estimated time to return to work of approximately 16 months. Following the accident, the front loader was removed from the work site and transported to a repair facility. Subsequent inspection revealed that a dual function hydraulic valve had failed, and a new part was installed before the loader was returned to duty. The brakes had been replaced on the loader two months prior to the accident and maintenance records showed that the loader had been properly maintained by the employer.
Keywords: FRACTURE, INSTALLING, BRAKE, CONSTRUCTION, EARTHMOVING EQUIP, TRENCH, EQUIPMENT FAILURE, CRUSHED, PELVIS, LOADER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120277140 | Hospitalized injury | Fracture | Occupation not reported |