Powered by GoogleTranslate

Inspection Detail

Inspection: 120275334 - San Diego Gas & Electric

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 120275334
Report ID: 0950632
Date Opened: 03/14/2001

Site Address:
San Diego Gas & Electric
Vista Sorrento Pkwy & Rose Coral Rd
San Diego, CA 92130

Mailing Address:
8330 Century Park Ct Cp31a, San Diego, CA 92123

Union Status: NonUnion

SIC:4911

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/14/2001

Emphasis:

Case Closed: 09/06/2001


Related Activity
Type Activity Nr Safety Health
Accident 362074205
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1
Initial Penalty $18,000 $0 $0 $400 $0 $18,400
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A07 C 08/17/2001 08/22/2001 $0 $400 $0 A - Amendment  
2. 02001 Serious 3706 A 08/17/2001 09/04/2001 $0 $18,000 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 201063641
Event: 03/05/2001
Employee Injured When Ankle Fractured by Truck's Stabilizer

A gas and electric utility was installing concrete underground manhole boxes for gas control valves. A crew of four employees was unloading a concrete box, measuring approximately 12 feet deep by 6 feet square, from the back bed of a boom truck parked in the middle of a road. One of the crewmembers was facing the truck, approximately 15 feet from the control panel, inserting a lifting knuckle into a lifting eye for the concrete box. The crew foreman was behind a screen, operating the truck's rear control switch. When the foreman extended the truck's stabilizers, the rear stabilizer landed on the left foot of the first crewmember. There was no warning device for the short rear stabilizer. There were no witnesses to the accident. Emergency medical services transported the injured employee to a hospital, where he was treated and released after 4 hours.

Keywords: BOOM TRUCK, FRACTURE, OUTRIGGER, STRUCK BY, MANHOLE, ANKLE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120275334 Non Hospitalized injury Fracture Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.