Inspection Detail
Inspection: 120274659 - Lights Ltd
Inspection Information - Office: San Diego District Office
Site Address:
Lights Ltd
1800 Zoo Place
San Diego, CA 92101
Mailing Address:
10658 Prospect Ave Ste D, Santee, CA 92071
Union Status: NonUnion
SIC:1731
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/20/2001
Emphasis:
Case Closed: 10/07/2002
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362065989 |
Investigation Summary
A full-time supervisor for a lighting contractor had been erecting a stage truss to support lighting for a show at an animal park. He was working from an unguarded elevated area on the side of the stage at a height of approximately 4.6 meters. He was trying to position a guy through some tree branches that were surrounding the stage. When he stepped back, his right foot went through a green skylight dome. He hit the back of his head on the dome frame and lost consciousness. He was hospitalized for 8 days with fractures to his c5 vertebra, lower back, and hip. He also suffered a shoulder injury and bruises to his lung.
Keywords: FRACTURE, ELECTRICIAN, BACK, FALL, FALL PROTECTION, ELEVATED WORK PLAT, VERTEBRA, HIP
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120274659 | Hospitalized injury | Fracture | Supervisors; electricians & power transm. install. |