Inspection Detail
Inspection: 1202708.015 - 70549 - Dak Americas Llc
Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation
Site Address:
70549 - Dak Americas Llc
570 K Avenue
Gaston, SC 29053
Mailing Address:
570 K Avenue, Gaston, SC 29053
Union Status: NonUnion
SIC:2821
NAICS: 325211/Plastics Material and Resin Manufacturing
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 05/11/2017
Emphasis:
Case Closed: 01/22/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Complaint | 1162779 | Yes | |
| Accident | 1161942 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $9,000 | $0 | $0 | $0 | $0 | $9,000 |
| Current Penalty | $9,000 | $0 | $0 | $0 | $0 | $9,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100147 C04 I | 05/23/2017 | 06/26/2017 | $4,500 | $4,500 | $0 | Z - Issued | ||
| 2. | 01002 | Serious | 19100147 D05 I | 05/23/2017 | 06/05/2017 | $4,500 | $4,500 | $0 | Z - Issued |
Investigation Summary
On December 6, 2016, an operations employee had already locked out the suction and discharge valves for pump AC-11. It was discovered that the drain line valve for AC-01 was faulty and could not open to drain hot monomer. A Safe Work Permit that called for a line break using an Unusual Job Permit (UJP) was issued on December 6, 2016 at 7:30 am. The pump jacket was drained of its heat transfer medium (HTM) oil into a black 55-gallon drum, prior to maintenance mechanics splitting open pump AC-11 for the first line break at around 12 noon to drain hot PET monomer. Once the maintenance mechanics had completed the first line break by separating the volute from the pump, hot PET monomer was expected to spill onto the floor around the pump, cool and solidify. Around 12:10 pm, a pressure blast occurred that blew out the right side of the pump about 10-15 feet through the air. The employee was struck by the blast and smashed into the adjacent concrete block wall. The employee was killed from the blast.
Keywords: Lockout/Tagout, Pressure Release, Struck By
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1202708.015 | 26 | M | Hospitalized injury | Occupation not reported | |
| 2 | 1202708.015 | 43 | M | Hospitalized injury | Occupation not reported | |
| 3 | 1202708.015 | 63 | M | Fatality | Occupation not reported |