Inspection Detail
Inspection: 120260328 - Mc Gill Corporation
Inspection Information - Office: Monrovia District Office
Site Address:
Mc Gill Corporation
4056 Easy Street
El Monte, CA 91731
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:5031
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/05/1999
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 09/11/2006
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 362545980 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 3 | 6 | |||
Current Violations | 2 | 4 | 6 | |||
Initial Penalty | $8,180 | $0 | $0 | $945 | $0 | $9,125 |
Current Penalty | $3,310 | $0 | $0 | $695 | $0 | $4,005 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 5144 K01 D | 11/05/1999 | 12/06/1999 | $260 | $315 | $0 | 12/03/1999 | F - Formal Settlement | |
2. | 01002 | Other | 4973 | 11/05/1999 | 12/06/1999 | $0 | $315 | $0 | 12/03/1999 | F - Formal Settlement | |
3. | 01003 | Other | 4650 E | 11/05/1999 | 12/06/1999 | $175 | $315 | $0 | 12/03/1999 | F - Formal Settlement | |
4. | 02001 | Other | 4838 A | 11/05/1999 | 12/06/1999 | $260 | $1,590 | $0 | 12/03/1999 | F - Formal Settlement | |
5. | 03001 | Serious | 4845 B | 11/05/1999 | 12/06/1999 | $1,310 | $1,590 | $0 | 12/03/1999 | F - Formal Settlement | |
6. | 04001 | Serious | 3328 F | 11/05/1999 | 12/06/1999 | $2,000 | $5,000 | $0 | 12/03/1999 | F - Formal Settlement |
Investigation Summary
At approximately 9:40 a.m. on August 3, 1999, Employee #1 was removing a large part, called a block, from dip tank Number 1 when the hoist pulley broke causing the block to swing horizontally and strike him in the chest. Employee #1 was pinned between the block and a large floor-mounted vent called a "purger." Coworkers saw employee #1 staggering out of the dip tank Number 1 area and provided assistance. Employee #1 had sustained serious injuries including a broken breast-bone and broken ribs. Employee #1 was hospitalized for 4 days. The employer had had an outside machine shop fabricate a new pulley about two weeks before the accident. After the accident the employer examined the broken pulley and determined it was not made to the same specifications as the original and because the specifications were not the same, grease was prevented from lubricating the parts. Therefore, the pulley seized and broke. The employer had failed to ensure that the new pulley was made to the original specifications.
Keywords: CHEST, FRACTURE, PINNED, EQUIPMENT FAILURE, HOIST, RIB, DIP TANK, STRUCK BY, PULLEY
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 120260328 | Hospitalized injury | Fracture | Occupation not reported |