Inspection Detail
Inspection: 120243753 - Aluminum Precision Products
Inspection Information - Office: Santa Ana District Office
Site Address:
Aluminum Precision Products
2621 S Susan St
Santa Ana, CA 92707
Mailing Address:
1971 E 4th St #130, Santa Ana, CA 92701
Union Status: NonUnion
SIC:3463
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/01/1999
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 07/23/2002
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Complaint | 78414174 | Yes | |
| Accident | 362390015 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $0 | $0 | $0 | $1,050 | $0 | $1,050 |
| Current Penalty | $0 | $0 | $0 | $1,050 | $0 | $1,050 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 342 A | 10/08/1999 | 10/14/1999 | $300 | $300 | $0 | - | ||
| 2. | 01002 | Other | 5162 E | 10/08/1999 | 10/26/1999 | $300 | $300 | $0 | - | ||
| 3. | 01003 | Other | 3328 G | 10/08/1999 | 10/14/1999 | $450 | $450 | $0 | - |
Investigation Summary
On May 11, 1999, an employee was injured while operating an aluminum forging press. A hydraulic fluid line ruptured and squirted flammable fluid onto the heated die area. This created a flame shooting towards the operator. The employee suffered second-and-third-degree burns to a large portion of his body.
Keywords: BURN, FIRE, HYDRAULIC FLUID, PRESS OPERATOR, PRESS
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120243753 | Hospitalized injury | Burn/Scald(Heat) | Forging machine operators |