Inspection Detail
Inspection: 120179312 - Ca Prison Industry Authority
Inspection Information - Office: Sacramento District Office
Site Address:
Ca Prison Industry Authority
300 Prison Rd
Represa, CA 95671
Mailing Address:
P.O. Box 290009, Represa, CA 95671
Union Status: Union
SIC:9223
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: StateGovt
Safety/Health: Safety
Close Conference: 05/23/1996
Emphasis:
Case Closed: 06/28/1996
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361506280 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 4208 A01 | 06/25/1996 | 06/28/1996 | $0 | $0 | $0 | - |
Investigation Summary
Employee #1, a prisoner, got his finger caught in the pinch point of a 50-ton press when a light curtain turned off. He sustained injuries that required hospitalization.
Keywords: POWER PRESS, FINGER, WORK RULES, POINT OF OPERATION, LIGHT CURTAIN, PRESS OPERATOR, PRESS
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120179312 | Hospitalized injury | Amputation | Punching and stamping press machine operators |
Translate