Inspection Detail
Inspection: 120177902 - Systems Engineering
Inspection Information - Office: Sacramento District Office
Site Address:
Systems Engineering
7340 French Road
Sacramento, CA 95828
Mailing Address:
P. O. Box 881, Brea, CA 92622
Union Status: NonUnion
SIC:8744
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/27/1994
Emphasis:
Case Closed: 08/03/1995
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361510639 | ||
Accident | 361510654 |
Investigation Summary
Employees #1 and #2, assistant engineers, were inspecting a dust collection system bag house. The employees followed safety procedures by taking oxygen readings before entering the sawdust collector. The readings were fine. One employee entered the collector and was removing and inspecting the filters, one by one. The other employee was in the bag house entryway. They were using a new, recently purchased, 110 volt halogen light. Apparently, the light became hot and ignited the dust with a flash. Employee #1 suffered burns to his face, arms, and leg and was hospitalized. Employee #2 suffered burns to his hands and was treated at the hospital and released.
Keywords: BURN, HEAT, CONFINED SPACE, WORK RULES, FIRE, LIGHTING FIXTURE, COMBUSTIBLE DUST, FACE, HAND, LEG
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 120177902 | Non Hospitalized injury | Burn/Scald(Heat) | Engineers, n.e.c. | ||
2 | 120177902 | Hospitalized injury | Burn/Scald(Heat) | Engineers, n.e.c. |