Inspection Detail
Inspection: 120165352 - Rs Elevator
Inspection Information - Office: Santa Ana District Office
Site Address:
Rs Elevator
900 N Broadway 10th Floor
Santa Ana, CA 92701
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3999
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/25/2002
Emphasis:
Case Closed: 06/06/2002
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362358723 |
Investigation Summary
On April 19, 2002, Employee #1 was in the elevator penthouse to observe elevator operation since it was starting and stopping in a jerky manner. The elevator was located in a 10-story office building in Santa Ana, California. While visually inspecting the elevator, Employee #1 reached into the braking system. His hand was pinched in the working mechanism of the elevator, between the braking system and the framework of the moving elevator. Employee #1's hand was severely lacerated. He was hospitalized.
Keywords: BRAKE, CAUGHT BETWEEN, LACERATION, ELEVATOR, HAND
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120165352 | Hospitalized injury | Cut/Laceration | Occupation not reported |