Inspection Detail
Inspection: 120161021 - Hydro Conduit Corp
Inspection Information - Office: Santa Ana District Office
Site Address:
Hydro Conduit Corp
23200 Temescal Cyn Rd
Corona, CA 91719
Mailing Address:
, , 00000
Union Status: Union
SIC:3272
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/30/1995
Emphasis:
Case Closed: 06/13/1995
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361331820 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $100 | $0 | $100 |
| Current Penalty | $0 | $0 | $0 | $100 | $0 | $100 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3314 B | 04/21/1995 | 04/26/1995 | $100 | $100 | $0 | - |
Investigation Summary
Employee #1 was doing a pre-operation inspection on a concrete mixer when a coworker started the mixer. The mixer had not been locked out by Employee #1. His spleen was ruptured and he was killed.
Keywords: MAINTENANCE, SPLEEN, WORK RULES, CONCRETE MIXER, LOCKOUT, RUPTURE, CRUSHED, COMMUNICATION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120161021 | Fatality | Puncture | Occupation not reported |
Translate