Inspection: 120160353 - Better Line Products Inc

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 120160353
Report ID: 0950631
Date Opened: 03/15/1995

Site Address:
Better Line Products Inc
1101 E Elm
Fullerton, CA 92635

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3599

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/15/1995

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 09/13/2010


Related Activity
Type Activity Nr Safety Health
Accident 362218000
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 4 5
Current Violations 1 4 5
Initial Penalty $1,200 $0 $0 $900 $0 $2,100
Current Penalty $1,200 $0 $0 $800 $0 $2,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 4202 C 04/07/1995 05/10/1995 $200 $225 $0 06/14/1995 J - ALJ Decision  
2. 01002 Other 3203 B01 04/07/1995 05/10/1995 $200 $225 $0 06/14/1995 J - ALJ Decision  
3. 01003 Other 342 A 04/07/1995 05/10/1995 $200 $225 $0 06/14/1995 J - ALJ Decision  
4. 01004 Other 3203 B02 04/07/1995 05/10/1995 $200 $225 $0 06/14/1995 F - Formal Settlement  
5. 02001 Serious 4206 A 04/07/1995 05/10/1995 $1,200 $1,200 $0 06/14/1995 F - Formal Settlement  

Investigation Summary

Investigation Nr: 170585301
Event: 03/01/1995
Employee's thumb fractured in punch press point of operation

At approximately 10:30 a.m. on March 1, 1995, Employee #1 was operating a 60-ton Minster mechanical part-revolution punch press. This punch press has can be activated by the use of a two-push-button control or by foot pedal. The selection of the type of activation is made by the use of a key. The punch press was on the foot pedal activation mode and the point of operation was not guarded. The key is left on the punch press and not controlled by the employer. Employee #1's right thumb got caught in the point of operation, resulting in a compound fracture. She was taken to St. Jude Medical Center-Fullerton for treatment and hospitalization and was released from the hospital the next day at 1:00 p.m.. The cause of the accident was that the punch press was not guarded. The employer is being cited for a serious violation T8CCR 4206(a).

Keywords: FRACTURE, WORK RULES, FOOT CONTROL, THUMB, CAUGHT BETWEEN, POINT OF OPERATION, PRESS OPERATOR, PUNCH PRESS, PRESS, UNGUARDED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120160353 Hospitalized injury Amputation Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.