Inspection Detail
Inspection: 120154364 - Bosley Electric Co
Inspection Information - Office: Ca Sacramento
Site Address:
Bosley Electric Co
2995 Oates St.
West Sacramento, CA 95691
Mailing Address:
935 Arden Way, Sacramento, CA 95815
Union Status: NonUnion
SIC:1731
NAICS: 238210/Electrical Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/09/2002
Planning Guide: Safety-Construction
Emphasis: S:Construction (Cship)
Close Case:06/22/2004
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361728975 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 3 | 4 | |||
Current Violations | 1 | 3 | 4 | |||
Initial Penalty | $24,300 | $0 | $0 | $1,000 | $0 | $25,300 |
Current Penalty | $14,400 | $0 | $0 | $1,000 | $0 | $15,400 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 341 A01 | 09/27/2002 | 10/07/2002 | $250 | $250 | $0 | 10/16/2002 | W - Empr Withdrew | |
2. | 01002 | Other | 342 A | 09/27/2002 | 10/02/2002 | $250 | $250 | $0 | - | ||
3. | 01003 | Other | 3203 A07 F | 09/27/2002 | 10/30/2002 | $500 | $500 | $0 | - | ||
4. | 02001 | Serious | 15410001 A01 B | 09/27/2002 | 10/07/2002 | $14,400 | $24,300 | $0 | 10/16/2002 | J - ALJ Decision |
Investigation Summary
A supervisory power line worker entered an unsecured excavation to clear some earth to enable him to run electrical conduit from a utility vault. As he was digging into the side of a vertical wall, he sensed a problem and started moving toward a ladder to exit the excavation. The side of the excavation adjacent to the vault caved in, burying the employee up to his knees. Other employees dug him out, and an emergency medical services team transported him to a hospital. He was hospitalized for 4 days with a fracture to his left leg.
Keywords:excavation, fracture, elec utility work, shoring, unstable soil, cave-in, leg
# | Inspection | Age | Sex | Degree | Nature | Occupation |
---|---|---|---|---|---|---|
1 | 120154364 | Hospitalized injury | Fracture | Supervisors; electricians & power transm. install. |