Powered by GoogleTranslate

Inspection Detail

Inspection: 120134861 - Torro Agricultural Irrigation

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 120134861
Report ID: 0950632
Date Opened: 09/26/1997

Site Address:
Torro Agricultural Irrigation
1588 N Marshall
El Cajon, CA 92020

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3084

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/13/1998

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 05/22/1998


Related Activity
Type Activity Nr Safety Health
Accident 362257891
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2 4
Current Violations 2 2 4
Initial Penalty $2,810 $0 $0 $745 $0 $3,555
Current Penalty $2,810 $0 $0 $745 $0 $3,555
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A03 01/15/1998 02/04/1998 $185 $185 $0 -  
2. 01002 Other 23200006 A 01/15/1998 02/04/1998 $560 $560 $0 -  
3. 02001 Serious 3314 H 01/15/1998 01/30/1998 $935 $935 $0 -  
4. 03001 Serious 23400001 01/15/1998 01/30/1998 $1,875 $1,875 $0 -  

Investigation Summary

Investigation Nr: 201060753
Event: 09/13/1997
electric shock - direct contact with energized parts

An employee was operating a PaceMaker II extruder machine that was used in making rubber hose products. A motor on the machine overheated and tripped the motor overload protection. The operator entered an electrical cabinet to reset the relay. The switch was defective, and the employee received an electric shock from the 480-volt disconnect when he attempted to push the switch and contacted energized parts. He was hospitalized for 48 hours for observation as a result of his injuries.

Keywords: E GI III, ELECTRICAL, ELECTRIC SWITCH, LOCKOUT, ELECTRIC SHOCK, UNTRAINED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120134861 Hospitalized injury Electric Shock Extruding and forming machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.