Powered by GoogleTranslate

Inspection Detail

Inspection: 120132220 - Ameron Concrete & Steel Pipe Systems

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 120132220
Report ID: 0950632
Date Opened: 11/08/1994

Site Address:
Ameron Concrete & Steel Pipe Systems
10441 Vine St
Lakeside, CA 92040

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3272

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/19/1995

Emphasis:

Case Closed: 03/07/1996


Related Activity
Type Activity Nr Safety Health
Accident 362249476
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 4 7
Current Violations 3 4 7
Initial Penalty $6,870 $0 $0 $740 $0 $7,610
Current Penalty $3,275 $0 $0 $740 $0 $4,015
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3638 A 05/01/1995 05/16/1995 $185 $185 $0 -  
2. 01002 Other 3638 B 05/01/1995 05/16/1995 $185 $185 $0 -  
3. 01003 Other 3642 A01 05/01/1995 05/01/1995 $185 $185 $0 -  
4. 01004 Other 3648 B 05/01/1995 05/01/1995 $185 $185 $0 -  
5. 02001 Serious 3210 A 05/01/1995 05/01/1995 $935 $935 $0 -  
6. 03001 Serious 4650 E 05/01/1995 05/01/1995 $935 $935 $0 -  
7. 04001 Serious 5031 A 05/01/1995 05/01/1995 $1,405 $5,000 $0 05/18/1995 W - Empr Withdrew  

Investigation Summary

Investigation Nr: 170892111
Event: 11/08/1994
Employee injured when struck in chest by falling steel cage

Employee #1 was welding rebar cages as they came out of an Acrowood 12-78 cage manufacturing machine, serial #4880-91, that was being operated by his coworker. The approximately 150 lb, cylindrical-shaped cages were made of reinforced steel welded with straight heavy gauge wire and were used as reinforcement in the manufacture of cement pipes. The coworker had cut loose a cage from the machine and was picking it up to lower it to Employee #1 when the 1/4 in. steel cable of the hoist broke. The cage fell and struck Employee #1 in the chest, knocking him unconscious for a brief period and inflicting chest trauma. He was given first aid until paramedics arrived, and then transported to the hospital, where he was admitted for three days. The hoist cable had not been changed even though it was noted to be worn. The employer was cited for a serious, accident-related violation of T8CCR 5031(a).

Keywords: CHEST, UNCONSCIOUSNESS, INADEQUATE MAINT, WORK RULES, WELDER, EQUIPMENT FAILURE, HOIST, STRUCK BY, FALLING OBJECT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120132220 Hospitalized injury Bruise/Contus/Abras Production helpers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close