Powered by GoogleTranslate

Inspection Detail

Inspection: 120124623 - Robert Shurtliff Dba Shurtliff Drywall Co.

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 120124623
Report ID: 0950633
Date Opened: 05/28/1999

Site Address:
Robert Shurtliff Dba Shurtliff Drywall Co.
1980 Orangetree Suite 105
Redlands, CA 92374

Mailing Address:
407-E Vankoever Ste, Rialto, CA 92376

Union Status: NonUnion

SIC:1742

NAICS: 238310/Drywall and Insulation Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/15/1999

Emphasis:

Case Closed: 01/19/2000


Related Activity
Type Activity Nr Safety Health
Accident 362476756
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 6 7
Current Violations 1 6 7
Initial Penalty $3,000 $0 $0 $1,000 $0 $4,000
Current Penalty $3,000 $0 $0 $1,000 $0 $4,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 1509 A 11/17/1999 12/20/1999 $175 $175 $0 -  
2. 01002 Other 1509 C 11/17/1999 12/20/1999 $85 $85 $0 -  
3. 01003 Other 1512 C 11/17/1999 12/20/1999 $85 $85 $0 -  
4. 01004 Other 23950059 B 11/17/1999 11/22/1999 $85 $85 $0 -  
5. 01005 Other 25000009 A 11/17/1999 11/22/1999 $285 $285 $0 -  
6. 01006 Other 25000010 A 11/17/1999 11/22/1999 $285 $285 $0 -  
7. 02001 Serious 1675 L 11/17/1999 11/22/1999 $3,000 $3,000 $0 -  

Investigation Summary

Investigation Nr: 201152535
Event: 05/27/1999
Electric Shock - Ground Fault in Cord Set

An employee was working from a 2.4-meter-tall portable aluminum stepladder, hanging a 1.3-meter by 1.2-meter piece of drywall at a height of 2.7 meters above the floor. A flexible conduit was hanging from the ceiling next to the ladder. One of the ladder's legs was sitting on an extension cord set, which was connected to the employee's Hilti drywall screw gun. When the employee pulled the extension cord, the leg of the ladder apparently penetrated the insulation on the cord. The employee received an electric shock and fell from the ladder to the concrete floor. He was hospitalized for several days with head injuries and electrical burns on his hands.

Keywords: BURN, HEAD, E GI III, ELECTRICAL, STEPLADDER, CORD SET, GROUND FAULT, METAL LADDER, ELECTRIC SHOCK, FALL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120124623 Hospitalized injury Electric Shock Drywall installers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.