Inspection Detail
Inspection: 120118518 - General Construction
Inspection Information - Office: Long Beach District Office
Site Address:
General Construction
101 W Torrance Blvd No 119a Redondo Beach Pier
Redondo Beach, CA 90277
Mailing Address:
20 Executive Park No 280, Irvine, CA 92714
Union Status: Union
SIC:1629
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/21/1994
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 07/19/1995
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362022402 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 1 | 1 | 2 | |||
| Initial Penalty | $5,000 | $0 | $0 | $380 | $0 | $5,380 |
| Current Penalty | $5,000 | $0 | $0 | $380 | $0 | $5,380 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3203 A04 | 07/07/1994 | 07/07/1994 | $380 | $380 | $0 | 08/04/1994 | W - Empr Withdrew | |
| 2. | 02001 | Serious | 3329 B | 07/07/1994 | 07/07/1994 | $5,000 | $5,000 | $0 | 08/04/1994 | W - Empr Withdrew |
Investigation Summary
Employee #1 was adjusting a bypass valve on a gel pile pump. The connection of the pipe to the elbow failed, throwing the pipe into Employee #1's face. Employee #1 sustained contusions to his cheekbones and eyes. Employee #1 was hospitalized for less than 24 hours and lost work due to a non-usable eye.
Keywords: EYE, VALVE, PIPE, FACE, PUMP, CONTUSION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120118518 | Non Hospitalized injury | Fracture | Construction trades, n.e.c. |