Powered by GoogleTranslate

Inspection Detail

Inspection: 120115688 - Corcom Inc

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 120115688
Report ID: 0950635
Date Opened: 02/07/1994

Site Address:
Corcom Inc
1201 W Francisco St
Torrance, CA 90502

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:8731

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/22/1994

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 06/13/1994


Related Activity
Type Activity Nr Safety Health
Accident 362022022
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 4 5
Current Violations 1 4 5
Initial Penalty $2,000 $0 $0 $1,200 $0 $3,200
Current Penalty $2,000 $0 $0 $1,200 $0 $3,200
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 23400016 A 02/25/1994 03/28/1994 $200 $200 $0 -  
2. 01002 Other 23400017 A 02/25/1994 03/28/1994 $200 $200 $0 -  
3. 01003 Other 3203 A 02/25/1994 03/28/1994 $400 $400 $0 -  
4. 01004 Other 14301 A02 02/25/1994 03/23/1994 $400 $400 $0 -  
5. 02001 Serious 14301 A02 02/25/1994 03/15/1994 $2,000 $2,000 $0 -  

Investigation Summary

Investigation Nr: 170586986
Event: 01/31/1994
ELECTRIC SHOCK - CONTACT WITH STORED CHARGE IN CAPACITOR

A PRODUCTION TESTER WAS REQUIRED TO PERFORM A QUALITY TEST OF POWER FILTERS FOR ELECTRONIC EQUIPMENT. IT WAS ASSUMED THAT THE CAPACITORS FOR THE POWER FILTERS WERE DISCHARGED; HOWEVER, THIS WAS NOT THE CASE. THE EMPLOYEE RECEIVED A 2250-VOLT ELECTRIC SHOCK WHEN HE LIFTED ONE OF THE FILTERS. THE FILTER'S CAPACITOR DISCHARGED WHEN THE EMPLOYEE CONTACTED ITS CONNECTORS.

Keywords: E GI IV, ELECTRICAL, ELECTRICAL TESTING, CAPACITOR, ELECTRONIC TECHNICN, LOCKOUT, TEST EQUIPMENT, ELECTRIC SHOCK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120115688 Non Hospitalized injury Electric Shock Production testers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.