Inspection Detail
Inspection: 120087861 - Mendota Bio Mass
Inspection Information - Office: Fresno District Office
Site Address:
Mendota Bio Mass
400 Guillen Parkway
Mendota, CA 93640
Mailing Address:
Po Box 99, Mendota, CA 93640
Union Status: NonUnion
SIC:1796
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/02/1994
Emphasis:
Case Closed: 11/02/1994
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361388424 |
Investigation Summary
Employee #1, of Men Dota Biomass Power Ltd., was servicing a plugged vent line in the lime feed system. He followed his employer's procedure of depressurizing the tank. He then disconnected the line and repressurized the line. The plug remained. Employee #1 then tapped the line with a hammer but was unable to dislodge the plug. He climbed the ladder and looked down the pipe at the same time the plug suddenly discharged. The plug struck Employee #1's defective safety glasses, shattering the lens. Employee #1's eye was destroyed by the impact.
Keywords: EYE, MAINTENANCE, PIPE PLUG, PPE, WORK RULES, CONSTRUCTION, EQUIPMENT FAILURE, HIGH PRESSURE, STRUCK BY, FLYING OBJECT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120087861 | Hospitalized injury | Foreign Body Ineye | Plumber, pipefitter and steamfiter apprentices |