Powered by GoogleTranslate

Inspection Detail

Inspection: 120080247 - Bostrom-Bergen Metal Products

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 120080247
Report ID: 0950643
Date Opened: 10/23/1995

Site Address:
Bostrom-Bergen Metal Products
100 Universal City Plaza
Universal City, CA 91608

Mailing Address:
3844 W. Ashlan Avenue, Fresno, CA 93792

Union Status: Union

SIC:1791

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/09/1996

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 12/05/1997


Related Activity
Type Activity Nr Safety Health
Accident 361273204
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2 4
Current Violations 1 2 3
Initial Penalty $5,375 $0 $0 $480 $0 $5,855
Current Penalty $1,375 $0 $0 $275 $0 $1,650
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3328 G 04/10/1996 05/03/1996 $0 $205 $0 L - State Settlement  
2. 01002 Other 1712 C01 04/10/1996 05/03/1996 $275 $275 $0 I - Informal Settlement  
3. 02001 Serious 3328 B 04/10/1996 05/03/1996 $0 $1,375 $0 I - Informal Settlement Citation has been deleted.
4. 03001 Serious 4851 E03 04/10/1996 05/03/1996 $1,375 $4,000 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 170151955
Event: 10/23/1995
FALL - WELDING CURRENT SEVERED SCAFFOLD SUPPORT CABLE

An employee was arc welding from a one-person suspended scaffold. The work lead on the welder had frayed insulation in one place, and the bare conductor was exposed. The frayed section of welding cable was tied around the metal guardrail of the scaffold. Since the scaffold was not grounded, it became energized. This caused arcing between the scaffold and the building. The welding current passed through the wire rope supporting the scaffold, and the wire rope separated. The employee and the scaffold fell 15 meters (50 feet) to the ground. The employee had been using an independent lifeline, but the heated wire rope apparently severed it. The employee was hospitalized for his injuries.

Keywords: E GI V, ELEC INSULATION, ELECTRICAL, WELDER, WELDING, EQUIPMENT FAILURE, SUPPORT CABLE, WELDING CABLE, FALL, SCAFFOLD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120080247 Hospitalized injury Fracture Welders and cutters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.