Powered by GoogleTranslate

Inspection Detail

Inspection: 120076914 - Dick Allen Yamaha Inc.

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 120076914
Report ID: 0950643
Date Opened: 08/16/1995

Site Address:
Dick Allen Yamaha Inc.
24601 Arch Street
Newhall, CA 91321

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:7699

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/21/1995

Emphasis:

Case Closed: 09/13/2010


Related Activity
Type Activity Nr Safety Health
Accident 362298481
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 8 10
Current Violations 2 8 10
Initial Penalty $4,060 $0 $0 $1,005 $0 $5,065
Current Penalty $4,060 $0 $0 $895 $0 $4,955
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 11/22/1995 12/16/1995 $110 $110 $0 -  
2. 01002 Other 5194 E01 11/22/1995 12/16/1995 $110 $110 $0 -  
3. 01003 Other 5194 G01 10/17/1995 10/27/1995 $0 $0 $0 -  
4. 01004 Other 6151 C01 10/17/1995 10/27/1995 $0 $0 $0 -  
5. 01005 Other 342 A 09/27/1995 09/27/1995 $225 $225 $0 -  
6. 01006 Other 14301 A01 09/27/1995 10/18/1995 $225 $225 $0 -  
7. 01007 Other 461 C 09/27/1995 10/27/1995 $225 $225 $0 -  
8. 02001 Serious 5417 C02 09/27/1995 10/11/1995 $3,500 $3,500 $0 -  
9. 03001 Other 5194 H01 09/27/1995 12/16/1995 $0 $110 $0 A - Amendment  
10. 04001 Serious 4070 A 10/17/1995 10/27/1995 $560 $560 $0 -  

Investigation Summary

Investigation Nr: 170151310
Event: 07/07/1995
Employee's hands and face burned in flash fire

On July 7, 1995, Employee #1, of Dick Allen Yamaha Inc., was told by his supervisor to use PJI super cleaner, a flammable contact cleaner, to displace water that had accumulated in the electrical box of a Seadoo watercraft. Employee #1 sprayed the cleaner on the wet electrical components, then used compressed air to evaporate the solvent. After evaporating the contact cleaner from the electrical box, Employee #1 placed his hand into the engine compartment. The battery was connected and one of the wires from the ignition system sparked inside the electrical box, igniting the accumulated vapors and causing a flash fire. Employee #1 suffered, second- and third-degree burns on his face and right hand. Employee #1 had failed to disconnect the battery, an ignition source, before spraying the flammable solvent into an area with poor ventilation. In addition, the employer failed to train Employee #1 on the hazards of using a flammable contact cleaner.

Keywords: BURN, VENTILATION, FLAMMABLE VAPORS, WORK RULES, FIRE, LOCKOUT, CLEANING FLUID, FACE, UNTRAINED, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 120076914 Hospitalized injury Burn/Scald(Heat) Not specified mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.