Inspection Detail
Inspection: 120069554 - Corbett Canyon Vineyards
Inspection Information - Office: Labor Enforcement Task Force (Letf) Unit - South
Site Address:
Corbett Canyon Vineyards
2195 Corbett Canyon Rd.
San Luis Obispo, CA 93403
Mailing Address:
P. O. Box 3159, San Luis Obispo, CA 93403
Union Status: NonUnion
SIC:2084
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/16/1995
Emphasis:
Case Closed: 08/22/1995
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362181802 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $150 | $0 | $150 |
| Current Penalty | $0 | $0 | $0 | $150 | $0 | $150 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3328 G | 03/10/1995 | 03/21/1995 | $150 | $150 | $0 | - |
Investigation Summary
At about 3:00 p.m. on January 25, 1994, Employee #1, of Corbett Canyon, was pumping wine from tanker trucks into 6,719 gallon tanks. When a tank that had been in service for more than 17 years was about 3/4 full, Employee #1 went to the tank door to check for leaks. He saw that it was leaking more than usual and attempted to tighten it. Before he could, the door flew open. The spilling wine knocked Employee #1 across the walkway into a conveyor trough. He was taken to the hospital, where he remained for four hours. The 18 in. by 18 in. hinged door to the tank has a 3/4 in. stainless bolt that swings on an 11 in. diameter aluminum bronze speed handle. The threads on the handle were worn and, as pressure in the tank built up, the threads gave way. Stainless steel is not used on the speed handle because it would gall-up (weld together) over the years. A general citation was issued to Corbett Canyon for failing to maintain safe operating conditions.
Keywords: LEAK, INADEQUATE MAINT, UNSECURED, WORK RULES, EQUIPMENT FAILURE, HIGH PRESSURE, SPILL, STRUCK BY, ACCIDENTAL DISCHARGE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 120069554 | Non Hospitalized injury | Bruise/Contus/Abras | Laborers, except construction |
Translate