Inspection Detail
Inspection: 120039417 - Allied Signal Inc
Inspection Information - Office: Los Angeles District Office
Site Address: 
			   Allied Signal Inc
			   850 S. Sepulveda Bl.
El Segundo, CA 90245
Mailing Address: 
			   , ,  00000
Union Status: Union
SIC:2869
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 10/13/1995
Emphasis:
Case Closed: 09/13/2010
| Type | Activity Nr | Safety | Health | 
|---|---|---|---|
| Accident | 362018194 | 
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total | 
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $2,500 | $0 | $0 | $300 | $0 | $2,800 | 
| Current Penalty | $0 | $0 | $0 | $300 | $0 | $300 | 
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 | 
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note | 
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 342 A | 10/17/1995 | 10/20/1995 | $300 | $300 | $0 | 03/28/1996 | L - State Settlement | Citation has been deleted. | 
| 2. | 02001 | Other | 3382 A | 10/17/1995 | 10/20/1995 | $300 | $2,500 | $0 | 03/28/1996 | J - ALJ Decision | 
Investigation Summary
At approximately 8:30 a.m. on May 9, 1995, Employee #1 was replacing a valve and purging the Y strainer on a high boiler waste stream tank. One end of a 4 to 5 ft long piece of 1/2 in. copper tubing had been connected to the strainer outlet and the other end had been placed in a plastic bucket that was filled with water. Employee #1 then opened the strainer drain valve to purge the system and observed the bubbling of the drained material, containing hydrochloric acid, hydrofluoric acid, and trichloroethane, into the water. The bubbling stopped before the employee thought it should have, so he closed the valve and removed the tubing from the strainer. As he reached for the water hose to wash out the tubing, liquid from the bucket splashed onto the left side of his face. It penetrated between the collar of his chemical resistant suit and face shield, resulting in severe burns to his face, neck, and ear. Employee #1 washed the affected area with the water hose he had in his hand and screamed for help. Another employee working in an adjacent area responded and put him under the emergency shower. Within 10 minutes, paramedics arrived and transported the employee to the hospital, where he was treated. He was released after 1:00 p.m. on May 10, 1995.
Keywords: TRICHLOROETHANE, HYDROCHLORIC ACID, PROTECTIVE CLOTHING, HYDROFLUORIC ACID, CHEMICAL BURN, PURGING, FACE, CHEMICAL
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation | 
|---|---|---|---|---|---|---|
| 1 | 120039417 | Hospitalized injury | Burn(Chemical) | Carpenter apprentices | 
 Translate
Translate