Inspection Detail
Inspection: 120036017 - International Die Casting
Inspection Information - Office: Los Angeles District Office
Site Address:
International Die Casting
14733 S. Avalon Blvd
Gardena, CA 90248
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3364
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/25/1996
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 07/24/1996
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 362019580 |
Investigation Summary
Employee #1, of International Die Casting, Gardena, CA, was engaged in his normally-assigned job operating a die casting machine. The machine was automatic in that the metal was not injected until the dies were closed and a metal safety shield was in place. An injection valve malfunctioned, resulting in the injector working with the dies open. Employee #1 was sprayed with molten metal and sustained first- and second-degree burns on his face and upper chest. He was wearing safety glasses and coveralls, which minimized his injuries.
Keywords: BURN, CHEST, DIE, WORK RULES, MOLTEN METAL, SPILL, DIE CASTING MACHINE, FACE, MECH MALFUNCTION, MACHINE--MISC
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 120036017 | Hospitalized injury | Burn/Scald(Heat) | Molding and casting machine operators |