Powered by GoogleTranslate

Inspection Detail

Inspection: 119990430 - W A Seeger Inc

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 119990430
Report ID: 0950632
Date Opened: 12/24/1992

Site Address:
W A Seeger Inc
696 Marsat Ct
Chula Vista, CA 91911

Mailing Address:
9966 Dolores St #101, Spring Valley, CA 91977

Union Status: NonUnion

SIC:1771

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/12/1993

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 09/28/1993


Related Activity
Type Activity Nr Safety Health
Accident 361368210
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 8 10
Current Violations 2 8 10
Initial Penalty $3,150 $0 $0 $3,600 $0 $6,750
Current Penalty $3,150 $0 $0 $3,600 $0 $6,750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 461 A 03/12/1993 03/12/1993 $750 $750 $0 -  
2. 01002 Other 1509 C 03/12/1993 03/12/1993 $150 $150 $0 -  
3. 01003 Other 3203 A 03/12/1993 04/12/1993 $150 $150 $0 -  
4. 01004 Other 465 D 03/12/1993 03/12/1993 $600 $600 $0 -  
5. 01005 Other 462 M01 03/12/1993 03/12/1993 $450 $450 $0 -  
6. 01006 Other 465 E 03/12/1993 03/12/1993 $450 $450 $0 -  
7. 01007 Other 462 B 03/12/1993 03/12/1993 $450 $450 $0 -  
8. 01008 Other 460 D 03/12/1993 03/12/1993 $600 $600 $0 -  
9. 02001 Serious 465 B01 03/12/1993 03/12/1993 $150 $150 $0 -  
10. 03001 Serious 454 A 03/12/1993 03/12/1993 $3,000 $3,000 $0 -  

Investigation Summary

Investigation Nr: 967265
Event: 12/24/1992
Employee injured in air tank explosion

The employer is engaged in parking lot maintenance and owns two identical portable paint stripping machines. The three major components of the machine are an air compressor unit, a paint supply can, and a 4 HP gas engine. The air tanks of the air compressor units did not have permits to operate and both were over 1 1/2 cu ft in capacity. One air tank exploded and Employee #1 sustained a fractured leg. The air tank did not meet ASME code and had deteriorated due to poor maintenance.

Keywords: COMPRESSOR, FRACTURE, INADEQUATE MAINT, WORK RULES, CONSTRUCTION, EXPLOSION, TANK, EQUIPMENT APPROVAL, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119990430 Hospitalized injury Fracture Painting and paint spraying machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close