Powered by GoogleTranslate

Inspection Detail

Inspection: 119970226 - Pour Concrete Removal & Cutting Inc

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 119970226
Report ID: 0950633
Date Opened: 04/23/1993

Site Address:
Pour Concrete Removal & Cutting Inc
9292 9th Street
Rancho Cucamonga, CA 91730

Mailing Address:
3839 California Avenue, Long Beach, CA 90807

Union Status: NonUnion

SIC:1771

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/26/1993

Emphasis:

Case Closed: 04/26/1993


Related Activity
Type Activity Nr Safety Health
Accident 361386907
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $4,500 $0 $0 $0 $0 $4,500
Current Penalty $1,935 $0 $0 $0 $0 $1,935
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 1509 A 10/18/1993 04/23/1993 $435 $3,000 $0 10/29/1993 W - Empr Withdrew  
2. 02001 Serious 23950051 A01 10/18/1993 04/23/1993 $1,500 $1,500 $0 -  

Investigation Summary

Investigation Nr: 170605190
Event: 04/21/1993
Employee killed when toluene vapors explode

At 3:20 p.m. on April 21, 1993, Employee #1 was using a Quadco-Wisconsin gas-powered concrete cutting machine, engine number W4-1770, to cut a concrete floor around an underground tank #17 in compounding room #2. The cutting machine hit a vent pipe 6 in. below the floor and flammable vapors of toluene that had been in the tank exploded. Employee #1 suffered severe burns over 85 percent of his body and was taken to San Bernadino County Medical Center. On April 28, 1993, he was airlifted to Sherman Oaks Medical Center, where he died at 7:00 a.m. on May 4, 1993. Employee #1 had worked at his position for three years, and was by himself at the job site. His employer had not visited the site prior to the accident. Openings on the manway of the underground tank had not been properly secured, allowing flammable vapors to escape.

Keywords: BURN, VAPOR, FLAMMABLE VAPORS, UNSECURED, WORK RULES, CONSTRUCTION, TOLUENE, EXPLOSION, CHEMICAL VAPOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119970226 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close