Inspection Detail
Inspection: 119968865 - Franklin Electric
Inspection Information - Office: San Bernardino District Office
Site Address:
Franklin Electric
19600 6th Street
Lakeview, CA 92567
Mailing Address:
10773 Central Place, Ontario, CA 91762
Union Status: NonUnion
SIC:1731
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/02/1993
Emphasis:
Case Closed: 09/17/1993
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362234973 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 4 | 5 | |||
| Current Violations | 1 | 4 | 5 | |||
| Initial Penalty | $4,500 | $0 | $0 | $1,375 | $0 | $5,875 |
| Current Penalty | $4,500 | $0 | $0 | $1,375 | $0 | $5,875 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 342 A | 08/09/1993 | 08/09/1993 | $250 | $250 | $0 | - | ||
| 2. | 01002 | Other | 341 A | 08/09/1993 | 08/09/1993 | $625 | $625 | $0 | - | ||
| 3. | 01003 | Other | 1541 J02 | 08/09/1993 | 08/09/1993 | $250 | $250 | $0 | - | ||
| 4. | 01004 | Other | 1541 K01 | 08/09/1993 | 08/09/1993 | $250 | $250 | $0 | - | ||
| 5. | 02001 | Serious | 15410001 A01 | 08/09/1993 | 08/09/1993 | $4,500 | $4,500 | $0 | - |
Investigation Summary
At approximately 11:20 a.m. on July 2, 1993, Employees #1 and #2 were working in an excavation that was approximately 12 feet deep, installing new electrical service to the Nutrilite Company of Lakeview, CA. Employees #1 and #2 were gluing plastic conduit at the bottom of the trench, which had been constructed by saw cutting a concrete drive and excavating the earth underneath. The vertical walls of the trench had not been protected against a cave-in by any means. As Employee #2 kneeled to fit together conduit pieces and Employee #1 stood applying glue to a different piece, the excavation's west wall caved in. Employee #2 was buried under approximately 4 feet of earth and Employee #1 was buried to his chest. The soil was very dry and sandy.
Keywords: EXCAVATION, INSTALLING, WORK RULES, CONSTRUCTION, TRENCH, SHORING, UNSTABLE SOIL, SLOPING, BURIED, CAVE-IN
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119968865 | Hospitalized injury | Fracture | Electrical power installers and repairers | ||
| 2 | 119968865 | Hospitalized injury | Fracture | Electrical power installers and repairers |
Translate