Inspection Detail
Inspection: 119968519 - L.A. Supply Label House
Inspection Information - Office: San Bernardino District Office
Site Address:
L.A. Supply Label House
9331 Commerce Way
Adelanto, CA 92301
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2759
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/14/1993
Emphasis:
Case Closed: 01/27/1994
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 362233603 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $500 | $0 | $0 | $0 | $0 | $500 |
Current Penalty | $500 | $0 | $0 | $0 | $0 | $500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 3314 A | 06/11/1993 | 06/11/1993 | $500 | $500 | $0 | - |
Investigation Summary
An employee was replacing a gear in an Allied Gear printing press. He had not deenergized or locked out hazardous energy sources for the press before he began servicing the machine. The employee contacted a 120-volt conductor for a component in the press and received an electric shock. He was transported to a hospital, evaluated, and released.
Keywords: MAINTENANCE, E GI IV, ELECTRICAL, LOCKOUT, ELECTRIC CONDUCTOR, ELECTRIC SHOCK
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 119968519 | Non Hospitalized injury | Electric Shock | Not specified mechanics and repairers |