Inspection Detail
Inspection: 119961704 - Kana Pipeline
Inspection Information - Office: San Bernardino District Office
Site Address:
Kana Pipeline
Old Temescal Canyon Road/California Avenue
Corona, CA 91720
Mailing Address:
Post Office Box 2817, Orange, CA 92669
Union Status: NonUnion
SIC:1623
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/12/1993
Emphasis:
Case Closed: 03/06/1995
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361385339 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $4,375 | $0 | $0 | $0 | $0 | $4,375 |
Current Penalty | $3,500 | $0 | $0 | $0 | $0 | $3,500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 3329 D | 09/16/1993 | 09/16/1993 | $3,500 | $4,375 | $0 | 10/19/1993 | Y - State Decision |
Investigation Summary
AT ABOUT 2:00 P.M. ON JULY 12, 1993, EMPLOYEE #1, A PIPELAYER, WAS DRILLING A 1-INCH HOLE INTO A NEWLY INSTALLED 8-INCH PVC PIPE IN ORDER TO INSTALL AN AIR VACUUM RELEASE. THE PIPE EXPLODED IN HIS FACE. EMPLOYEE #1 WAS UNAWARE THAT THE PIPE HAD BEEN PRESSURIZED BY THE ADMITTANCE OF WATER.
Keywords: CONSTRUCTION, EXPLOSION, PRESSURE PIPING, PIPE, FACE, INATTENTION
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 119961704 | Hospitalized injury | Other | Occupation not reported |