Powered by GoogleTranslate

Inspection Detail

Inspection: 119957454 - Industrial Wire Products Corporation

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 119957454
Report ID: 0950633
Date Opened: 02/14/1997

Site Address:
Industrial Wire Products Corporation
12459 Arrow Route
Etiwanda, CA 91739

Mailing Address:
, , 00000

Union Status: Union

SIC:3315

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/14/1997

Emphasis:

Case Closed: 08/12/1997


Related Activity
Type Activity Nr Safety Health
Accident 362040008

Investigation Summary

Investigation Nr: 201150588
Event: 02/07/1997
Employee's thumb tip amputated in wire drawing machine

At approximately 5:15 a.m. on February 7, 1997, Employee #1 was cleaning the bull block of a D-8 wire drawing machine when he inadvertently amputated the distal end of his right thumb. Employee #1 was transported to Loma Linda University Medical Center, where he was treated and released.

Keywords: AMPUTATED, CLEANING, CAUGHT BY, THUMB, WIRE DRAWING MACHINE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119957454 Non Hospitalized injury Amputation Misc. metal & plastic processing machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.