Powered by GoogleTranslate

Inspection Detail

Inspection: 119939569 - Sawing Services Co.

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 119939569
Report ID: 0950643
Date Opened: 01/18/2001

Site Address:
Sawing Services Co.
20871 Plummer St.
Chatsworth, CA 91311

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:7389

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/22/2001

Emphasis:

Case Closed: 04/15/2003


Related Activity
Type Activity Nr Safety Health
Accident 362505836
Accident 362504847
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $12,600 $0 $0 $225 $0 $12,825
Current Penalty $12,600 $0 $0 $225 $0 $12,825
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 06/25/2001 06/28/2001 $225 $225 $0 08/02/2001 W - Empr Withdrew  
2. 02001 Serious 3328 C 06/25/2001 07/09/2001 $12,600 $12,600 $0 08/02/2001 J - ALJ Decision  

Investigation Summary

Investigation Nr: 201113073
Event: 12/26/2000
Employee amputates thumb with plate saw

On December 26, 2000, Employee #1 was operating the "Goff" plate saw, Model S-4T, Serial Number TRW Systems 1 to cut aluminum pieces to a rectangular dimension of 0.25-in. thick by 48-in. long by 2-in. wide. He set the machine to make 0.25-in. thick horizontal strips. After the machine cut the aluminum, he stacked them in pairs of two or three strips, and then place them into the saw to cut vertical strips. Once the aluminum strip bars were placed into the saw for the vertical cut, he set a clamp to secure the material. Furthermore, a plastic shield lowered guarding the cutting path as the clamp was set. He then pushed the start button and the saw blade cut from right to left and return to the start position. Employee #1 removed the clamps by operating the levers located on the upper left side of the machine, and moved the material back in order to remove the cut strip. As he was removed the cut strip with his left hand, the blade came out of the start position, without being activated by the start button, and traveled across the table contacting his left hand. The blade amputated his thumb and damaged the nerves and tendons in his left palm. He was hospitalized in receive orthopedic surgery for attached the severed thumb. However, the reattachment was not successful, and the thumb was removed. Employee #1 was hospitalized for three weeks initially and then re- hospitalized for 12 days for additional surgery on the injured hand.

Keywords: ROTATING PARTS, AMPUTATED, ALUMINUM PROCESSING, GUARD, THUMB, SAW, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119939569 Hospitalized injury Amputation Sawing machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.