Inspection Detail
Inspection: 119939569 - Sawing Services Co.
Inspection Information - Office: Van Nuys District Office
Site Address:
Sawing Services Co.
20871 Plummer St.
Chatsworth, CA 91311
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:7389
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/22/2001
Emphasis:
Case Closed: 04/15/2003
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362505836 | ||
| Accident | 362504847 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 1 | 1 | 2 | |||
| Initial Penalty | $12,600 | $0 | $0 | $225 | $0 | $12,825 |
| Current Penalty | $12,600 | $0 | $0 | $225 | $0 | $12,825 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 342 A | 06/25/2001 | 06/28/2001 | $225 | $225 | $0 | 08/02/2001 | W - Empr Withdrew | |
| 2. | 02001 | Serious | 3328 C | 06/25/2001 | 07/09/2001 | $12,600 | $12,600 | $0 | 08/02/2001 | J - ALJ Decision |
Investigation Summary
On December 26, 2000, Employee #1 was operating the "Goff" plate saw, Model S-4T, Serial Number TRW Systems 1 to cut aluminum pieces to a rectangular dimension of 0.25-in. thick by 48-in. long by 2-in. wide. He set the machine to make 0.25-in. thick horizontal strips. After the machine cut the aluminum, he stacked them in pairs of two or three strips, and then place them into the saw to cut vertical strips. Once the aluminum strip bars were placed into the saw for the vertical cut, he set a clamp to secure the material. Furthermore, a plastic shield lowered guarding the cutting path as the clamp was set. He then pushed the start button and the saw blade cut from right to left and return to the start position. Employee #1 removed the clamps by operating the levers located on the upper left side of the machine, and moved the material back in order to remove the cut strip. As he was removed the cut strip with his left hand, the blade came out of the start position, without being activated by the start button, and traveled across the table contacting his left hand. The blade amputated his thumb and damaged the nerves and tendons in his left palm. He was hospitalized in receive orthopedic surgery for attached the severed thumb. However, the reattachment was not successful, and the thumb was removed. Employee #1 was hospitalized for three weeks initially and then re- hospitalized for 12 days for additional surgery on the injured hand.
Keywords: ROTATING PARTS, AMPUTATED, ALUMINUM PROCESSING, GUARD, THUMB, SAW, HAND
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119939569 | Hospitalized injury | Amputation | Sawing machine operators |