Powered by GoogleTranslate

Inspection Detail

Inspection: 119939171 - Nilavi Corp. Dba Sher-Mar

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 119939171
Report ID: 0950643
Date Opened: 06/15/1999

Site Address:
Nilavi Corp. Dba Sher-Mar
8755 Remmet Avenue
Chatsworth, CA 91311

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2844

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/23/1999

Emphasis:

Case Closed: 09/13/2010


Related Activity
Type Activity Nr Safety Health
Accident 362501215
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 2 7
Current Violations 5 2 7
Initial Penalty $14,350 $0 $0 $435 $0 $14,785
Current Penalty $14,350 $0 $0 $435 $0 $14,785
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 11/23/1999 12/27/1999 $175 $175 $0 01/14/2000 D - Govt Dismissed  
2. 01002 Other 5144 C02 B 11/23/1999 12/27/1999 $260 $260 $0 01/14/2000 D - Govt Dismissed  
3. 02001 Serious 5416 A 11/23/1999 12/03/1999 $4,200 $4,200 $0 01/14/2000 D - Govt Dismissed  
4. 03001 Serious 5417 E 11/23/1999 12/03/1999 $875 $875 $0 D - Govt Dismissed  
5. 04001 Serious 5534 B02 11/23/1999 12/03/1999 $4,200 $4,200 $0 01/14/2000 D - Govt Dismissed  
6. 05001 Serious 5549 A 11/23/1999 12/03/1999 $4,200 $4,200 $0 01/14/2000 D - Govt Dismissed  
7. 06001 Serious 3203 A04 11/23/1999 12/03/1999 $875 $875 $0 01/14/2000 D - Govt Dismissed  

Investigation Summary

Investigation Nr: 201112042
Event: 06/14/1999
Employee dies from flash fire of toluene vapors

In the afternoon of June 14, 1999, Employee #1 was preparing to mix a batch of nail polish working in a room 40 ft by 40 ft with a ventilation system moving 500 cubic feet per minute. He needed to obtain 35 pounds of toluene from a 55-gallon drum. He attempted to bond the pump to the drum using a Number 12 copper wire which was hand twisted onto a spring clip. The toluene was to be transferred to a bucket sitting on a metal scale, neither of which was bonded. A static charge built up and ignited vapors of toluene which had collected on the floor causing and explosion and fire. Employee #1 was severely burned and later died.

Keywords: DRUM, FIRE, TOLUENE, EXPLOSION, BONDING, CHEMICAL BURN, CHEMICAL VAPOR, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119939171 Fatality Burn/Scald(Heat) Chemical technicians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close