Powered by GoogleTranslate

Inspection Detail

Inspection: 119916658 - Sears Auto Center

Inspection Information - Office: Labor Enforcement Task Force (Letf) Unit - South

 

Inspection Nr: 119916658
Report ID: 0950645
Date Opened: 05/24/1994

Site Address:
Sears Auto Center
273 Madonna Road
San Luis Obispo, CA 93401

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5311

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/26/1994

Emphasis:

Case Closed: 11/30/1994


Related Activity
Type Activity Nr Safety Health
Accident 362156168
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 6 7
Current Violations 1 6 7
Initial Penalty $5,000 $0 $0 $1,215 $0 $6,215
Current Penalty $5,000 $0 $0 $615 $0 $5,615
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 06/06/1994 06/09/1994 $375 $375 $0 -  
2. 01002 Other 3543 B 06/06/1994 07/08/1994 $185 $280 $0 A - Amendment  
3. 01003 Other 3329 D 06/06/1994 06/09/1994 $55 $560 $0 A - Amendment  
4. 02001 Serious 3203 A07 C 06/06/1994 06/09/1994 $5,000 $5,000 $0 -  
5. 03001 Other 3203 A02 06/06/1994 07/08/1994 $0 $0 $0 -  
6. 03002 Other 3203 B02 06/06/1994 07/08/1994 $0 $0 $0 -  
7. 03003 Other 461 C 06/06/1994 06/17/1994 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 170719504
Event: 05/17/1994
Employee's finger broken when struck by oil reservoir plug

At about 12:30 p.m. on May 17, 1994, Employee #1 was checking the oil level on the H auto lift (muffler), which has two valves for raising and lowering the lift. The 1st valve has a small handle and when it is set to the right and the large handle is pulled it puts pressure into the tanks to raise the lift. To lower the lift, the small handle must be set to the left to release the pressure and the large handle must be pulled. The small handle can be set in the center (neutral) and will hold the lift in whichever way it came. Employee #1 set the small handle into the center, thinking this released the pressure. It did not, and when he took off the plug that was set in the floor, to check the oil level, the plug blew off. The plug hit his left middle finger and broke it. As he fell backward, he hit his head on the concrete floor.

Keywords: HEAD, HYDRAULIC LIFT, FINGER, WORK RULES, STRUCK AGAINST, HIGH PRESSURE, FALL, STRUCK BY, FLYING OBJECT, LOST BALANCE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119916658 Hospitalized injury Concussion Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.