Inspection Detail
Inspection: 119913093 - American Products
Inspection Information - Office: Labor Enforcement Task Force (Letf) Unit - South
Site Address:
American Products
1095 W. Los Angeles Ave.
Moorpark, CA 93021
Mailing Address:
P.O. Box 8085, Moorpark, CA 93020
Union Status: NonUnion
SIC:3823
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/22/1992
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 08/05/1993
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361396369 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $1,000 | $0 | $1,000 |
| Current Penalty | $0 | $0 | $0 | $1,000 | $0 | $1,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3301 C | 11/19/1992 | 12/18/1992 | $1,000 | $1,000 | $0 | - |
Investigation Summary
At 10:52 a.m. on October 20, 1992, a faulty V-clamp attached to a pool filter unit exploded while under pressure testing. Employee #1 suffered minor abdominal trauma and was treated and released from the Simi Valley Adventist Emergency Room. There was no protection surrounding the unit and the employer said that the clamp may have been overpressurized (12 psi normal). A citation was issued for a violation of 3301(k).
Keywords: ABDOMEN, WORK RULES, EQUIPMENT FAILURE, EXPLOSION, HIGH PRESSURE, STRUCK BY
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119913093 | Non Hospitalized injury | Other | Assemblers |