Inspection Detail
Inspection: 119908127 - Simi Valley Plumbing
Inspection Information - Office: Labor Enforcement Task Force (Letf) Unit - South
Site Address:
Simi Valley Plumbing
3385 Corpus Christie Road
Simi Valley, CA 93063
Mailing Address:
3770 E. Los Angeles Avenue, Simi Valley, CA 93003
Union Status: NonUnion
SIC:1711
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/27/1994
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 11/20/1998
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 362181042 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $0 | $0 | $0 | $225 | $0 | $225 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 23200001 A | 07/12/1994 | 07/20/1994 | $0 | $225 | $0 | 08/03/1994 | J - ALJ Decision |
Investigation Summary
A plumber's helper was grounding an electrical enclosure mounted on the exterior of a residential garage. The enclosure was a 100-ampere meter box made by Federal Pacific (Model or Serial No. MB-112-20-SF) mounted 48 inches above the ground. The employee had installed the copper rod grounding electrode and had attached an 8 AWG uninsulated conductor to it. As he was molding the wire to the contour of the building, the other end of the conductor snaked its way under the box cover through the hinge slot and contacted the 120/240-volt meter bus. The employee received an electric shock. Emergency medical services checked the employee and advised him to see a doctor. The employee was subsequently admitted to a hospital for his injury. (The employee had been instructed to carry out this task by a local building inspector.)
Keywords: E GI III, ELECTRICAL, ELECTRICAL WORK, ELECTRIC CONDUCTOR, ELECTRIC SHOCK, SYSTEM GROUNDING, ELECTRICAL BOX, UNTRAINED
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 119908127 | Hospitalized injury | Electric Shock | Plumber, pipefitter and steamfiter apprentices |