Inspection: 119891075 - Microwave Tower Service Inc
Inspection Information - Office: San Bernardino District Office
Site Address:
Microwave Tower Service Inc
72500 Varner Road
Cathedral City, CA 92234
Mailing Address:
1930 Lewis Street, Salem, OR 97302
Union Status: NonUnion
SIC:4899
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/10/1994
Emphasis:
Case Closed: 11/07/1994
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 362231565 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | 2 | |||
Current Violations | 1 | 1 | 2 | |||
Initial Penalty | $3,500 | $0 | $0 | $150 | $0 | $3,650 |
Current Penalty | $3,500 | $0 | $0 | $150 | $0 | $3,650 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 342 A | 07/13/1994 | 07/13/1994 | $150 | $150 | $0 | - | ||
2. | 02001 | Serious | 8615 J01 | 07/13/1994 | 07/13/1994 | $3,500 | $3,500 | $0 | - |
Investigation Summary
Two employees were measuring the height of a microwave communications antenna. One of the employees had climbed to a height of about 60 feet, about halfway up the 120-foot tower. While he was deploying a nylon-clad, steel tape measure, a gust of wind blew the tape into a 12-kilovolt overhead power line. The employee on the tower received an electric shock and burns. He was hospitalized for his injuries.
Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, TELECOM WORK, MEASURING DEVICE, E TC, ELECTRIC SHOCK, ANTENNA
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 119891075 | Hospitalized injury | Electric Shock | Misc. electrical & electronic equipment repairers |