Inspection Detail
Inspection: 119889186 - Richardson'S Rv Center
Inspection Information - Office: Santa Ana District Office
Site Address:
Richardson'S Rv Center
26786 Encanto Dr
Sun Center, CA 92585
Mailing Address:
10714 Indiana Ave, Riverside, CA 92405
Union Status: NonUnion
SIC:5561
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/18/2001
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 01/30/2001
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362397614 |
Investigation Summary
Employee #1, a service technician, was removing a gauge insert from an RV propane tank. He inadvertently removed the screws from the seal and the leaking propane ignited from the cordless drill/driver. He suffered burns to his arms, face, and hand.
Keywords: BURN, LEAK, EXPLOSION, PROPANE, ARM, FACE, HAND
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119889186 | Hospitalized injury | Burn/Scald(Heat) | Machinery maintenance occupations |
Translate